Ion conductance microscopy patch clamp

Scanning ion conductance microscopy specifications scan head controller the ionscope scanning ion conductance microscope sicm is a stateoftheart nanometer imaging system. In sicm, the probe to sample distance is controlled via the decrease of ionic current flowing through the tip, as it approaches the sample surface. We used scanning ion conductance microscopy and conventional cellattached patch clamp with a software modification that allows controlled. Scanning ionconductance microscopy is a scanning probe microscopy technique that uses an electrode as the probe tip. In this paper, live rat ventricular cardiomyocyte cells were examined with targeted patch clamping using a park sicm.

How do i calculateplot a conductancevoltage curve from. Sep 18, 20 nanoscaletargeted presynaptic ion channel patch clamp recordings. The combination of this technique with optical and fluorescence techniques permits correlation of cell function with spatial information. Patch clamping is vital to the study of excitable cells such as neurons, cardiomyocites, and muscle fiber in electrophysiology because the technique allows the researcher to examine single or multiple ion channels in those cells. We used scanning ion conductance microscopy and conventional cellattached patch clamp with a software modification that allows controlled increase of pipette tip diameter. A single ion channel conducts around 10 million ions per second. In this study, early responses of living human alveolar epithelial a549 cells after exposure to nzno were investigated by noncontact hopping probe ion conductance microscopy hpicm that was combined with the patch clamp technique. Ion conductance microscopy, live cell, noninvasive, biophysical applications, imaging. More recently, in combination with confocal microscopy and patchclamp electrophysiological techniques, sicm allows investigators to localize. It is thus of special interest in the research of excitable cells such as neurons, cardiomyocytes and muscle fibers. Hopping probe ion conductance microscopy and its combined patchclamping. It is intended for postgraduate students, postdoctoral workers or established scientists applying the techniques in their research.

The workshop provides intensive practical tuition in a number of microelectrode, patch clamp and optical techniques applied to single cells and whole tissues. Scanning ion conductance microscopy sicm is a scanning probe technique that utilizes the increase in access resistance that occurs if an electrolyte filled glass micropipette is approached towards a poorly conducting surface. Scanning ion conductance microscopy sicm is a new microscopy technique that is. More recently, in combination with confocal microscopy and patch clamp electrophysiological techniques. In summary, sicm bridges physics and biology to enable a range of important biomedical applications. Targeted patch clamping tpc combines patch clamping with ion conductance microscopy icm to guide the pipette to a specific patch clamping position. Optically guided patch clamp prevents the collection of any information on the position or type of cellular structure. University of nevada, reno two electrode voltage clamp tevc based scannin g ion conductance microscopy. Targeted patch clamping tpc 1 combines patch clamping with ion conductance microscopy sicm 2 to guide the pipette to a specific patch clamping position.

A patch clamp recording of current reveals transitions between two conductance states of a single ion channel. Sicm allows for the determination of the surface topography of micrometer and even nanometerrange structures in aqueous media conducting electrolytes. Microelectrode techniques for cell physiology marine. Targeted patch clamping with ion conductance microscopy. Patch clamp electrophysiology instruments used to evaluate ion channel behavior. The smart patch clamp method combines the scanning ion conductance microscopy sicm and patch clamp recording through a single glass nanopipette probe. Mspatchclamp or the possibility of mass spectrometry.

Two electrode voltage clamp tevc based scannin g ion. New m ethodology and validation a thesis submitted in partial fulfillment of the requirements for the degree of master of science. Nov 14, 2003 a specialized scanning ion conductance microscope sicm for imaging living cells has been developed from a conventional patch. When incorporated with scanning ion conductance microscopy sicm, the open barrel sicm barrel serves to measure the distancedependent ion current for n single entity electrochemistry. Calculating conductanceresistance from patchcurrent clamp. A brief summary of different applications of scanning ion conductance microscopy sicm in topography imaging, ion channel event recording, mechanical stimulation, simultaneous ion current and electrochemical current recording, localized delivery, single cell sampling and transport studies. Ion channels in small cells and subcellular structures can be. The scanning patch clamp technique combines scanning ion conductance microscopy and patch clamp recording through a single glass nanopipette probe. A new technique was developed with the aim of performing patch clamp at a specified position on the cell surface in contrast to conventional patch clamping with light microscopeaided guidance, where the position of the pipette in respect to the cell. Sep 18, 20 novak and colleagues have developed a method for nanoscaletargeted patch clamp presynaptic recordings in submicrometer central synapses identified using superresolution scanning ion conductance microscopy. Scanning ion conductance microscope sicm, which enables highresolution imaging of cell surface topography, has been developed for over two decades. Nov 06, 2012 scanning ion conductance microscopy sicm is a scanning probe technique that utilizes the increase in access resistance that occurs if an electrolyte filled glass micropipette is approached towards a poorly conducting surface. In traditional sicm, a micro or nanopipet is rastered over a surface of interest bathed in an electrolyte solution. In this method the nanopipette is first scanned over a.

Investigation of morphological and functional changes during neuronal differentiation of pc12 cells by combined hopping probe ion conductance microscopy and patch clamp technique article jul 2011. Examples include pcr, automated dna sequencing, confocalsingle photon microscopy, afm, and voltage patch clamp methods. However, only recently, a unique scanning mode is increasingly used in biological studies to allow sicm to detect the surface of live cells. It has significant advantages for measuring ionic conductance compared to alternative systems. Nov 22, 2015 this paper provides a current literature analysis comparing the possibilities of the novel approach proposed with the known methods, such as scanning patchclamp, scanning ion conductance microscopy, patch clamp based on scanning probe microscopy technology, quantitative subcellular secondary ion mass spectrometry or ion microscopy, live. Membrane patches as ion channel probes for scanning ion.

Highresolution scanning patch clamp technique enables the study of ion channels in small cells and submicrometer cellular structures. The patch clamp method, first described nearly 30 years ago, was a major. In this chapter we describe a novel advanced patchclamp technique, smart patchclamp, which enables the study of functional ion channels in the cell surface microdomains in a wide variety of biological cells and tissues. The scanning ion conductance microscope for cellular.

The smart patch clamp method combines the scanning ion conductance microscopy sicm and patchclamp recording through a single glass nanopipette probe. We have developed a scanning patch clamp technique that facilitates singlechannel recording from small cells and submicron cellular structures that are inaccessible by conventional methods. Icappic is a manufacturer of nanoanalytical instruments particularly scanning ion conductance microscope sicm systems and related equipment for a broad range of applications related to electrophysiology, ionchannel pharmacology and other biomedical applications. Specific aimsstudies suggest that cell specialization is often governed by the unique spatial distribution of ion channels on the cell surface, but the functional localization of ion channels is no. Design and construction of a scanning ion conductance. The sicm pipette can be used for patchclamp recordings of membrane potential and single channel currents. Sicm of live cells scanning ion conductance microscopy. The scanning ionconductance microscope sicm was invented by hansma and coworkers at the university of california in 1989 hansma et al. Patch clamp electrophysiology, voltage clamp, action. Here, we utilize micropipets with supported blms that incorporate ion channels, referred to as ion channel probes icps, as the probe for scanning ion conductance microscopy sicm figure 1. Cellattached patchclamp recordings of ion channels in small central.

Hopping probe ion conductance microscopy and its combined. Angular approach scanning ion conductance microscopy. Nanoscaletargeted patchclamp recordings of functional. Keywords scanning probe microscopy, scanning ion conductance microscopy, live cell, imaging, patch clamp, bio. The optical patch clamp solution by dhm is a simple alternative method to electrophysiology for many applications without strong electrophysiologist background or dedicated electrophysiological set up. The patch clamp electrode can gather topographic information of the cell surface that can be used to facilitate singlechannel recordings from small cells and submicron cellular structures that. Nanoscaletargeted presynaptic ion channel patchclamp.

The sicm pipette can be used for patchclamp recordings of. Smart patchclamp combines conventional patchclamp and scanning ion conductance microscopy sicm. Monitoring cell movements and volume changes with pulse. Targeted patch clamping with scanning ion conductance microscopy. The patch clamp electrode can gather topographic information of the cell surface that can be used to facilitate singlechannel recordings from small cells and submicron cellular structures that are inaccessible by conventional methods gorelik et al. In scanning nearfield optical microscopy, scanning ion conductance microscopy and for localized electrochemical deposition out of micropipettes, the detection of shear forces between the tip and. The patchclamp method, first described nearly 30 years ago, was a major.

Ion channel probes for scanning ion conductance microscopy. In this chapter we describe a novel advanced patchclamp technique, smart. It comprises a scan head, a controller, and dataacquisition systems. A specialized scanning ion conductance microscope sicm for imaging living cells has been developed from a conventional patch. This paper provides a current literature analysis comparing the possibilities of the novel approach proposed with the known methods, such as scanning patchclamp, scanning ion conductance microscopy, patch clamp based on scanning probe microscopy technology, quantitative subcellular secondary ion mass spectrometry or ion microscopy, live. The samples can be hard or soft, are generally nonconducting, and the nondestructive nature of the measurement allows for the observation of living tissues and cells, and biological samples in general. The patch clamp technique is a laboratory technique in electrophysiology used to study ionic currents in individual isolated living cells, tissue sections, or patches of cell membrane. Examples include pcr, automated dna sequencing, confocalsingle photon microscopy, afm, and voltagepatchclamp methods. The smart patch clamp also recorded ion channel currents from opaque samples e. The robust mechanical design of the ionscope sicm ensures high precision measurements.

Resolving single ion channels however with diameters of a few nanometers and imaging their distribution on the surface of the cell is much more challenging. Scanning ion conductance microscopy sicm is a scanning probe microscopy technique that uses an electrode as the probe tip. Superresolution scanning patch clamp reveals clustering of. The scanning patchclamp technique combines scanning ion conductance microscopy and patchclamp recording through a single glass nanopipette probe.

The method, heretofore called superresolution scanning patch clamp for its conceptual analogy to optical methods that enhance the resolution of an imaging system into the nanoscale superresolution microscopy, 10 uses the platform of scanning ion conductance microscopy sicm 11 combined with conventional cellattached patch clamp. In a wide family of scanning probe microscopes, sicm is the most recently developed one which is speci. Here, we describe the designs that allow mounting sicm scan head on a standard patchclamp micromanipulator and imaging the sample at an. Sicm scanning ion conductance microscopy is an spm technique which uses nanopipette sharp glass electrode for noncontact 3d surface mapping at high resolution. Recording singlechannel currents using smart patchclamp. Targeted patch clamping with scanning ion conductance. Patch clamping is vital to the study of excitable cells such as neurons, cardiomyocites, and muscle fiber in electrophysiology because the technique allows the researcher to examine single. Scanning ion conductance microscopy for studying biological. The patch clamp technique allows the investigation of a small set or even single ion channels. Scanning ion conductance microscopic study for cellular. This semiautomated approach opens a new window on the physiology of small presynaptic terminals. A powerful tool for structural and functional studies in neural nanobiology. We describe dualbarrel ion channel probes icps, which consist of an open barrel and a barrel with a membrane patch directly excised from a donor cell. Classical patch clamp setup, with microscope, antivibration table, and micromanipulators.

689 983 1575 1297 943 1468 316 824 325 956 1095 362 1026 1506 632 1423 837 1497 1393 490 955 247 576 374 127 1266 1013 743 368 161 609 1082 502 1207 1153